DELTA®-FASSADE S
The extreme UV resistance of this water-resistive barrier makes it particularly suitable for use in open joint cladding systems. The watertight membrane is highly vapor permeable and extremely tear resistant
Its excellent stability against ultra violet light means no doubling up of the membrane and no sacrificial layers. DELTA®-FASSADE S provides sustainable moisture protection behind open joint claddings for many years of service.
DELTA®-FASSADE S, highly stabilized against damage from UV exposure, is designed for use in cladding systems that have open joints of up to 2” (50 mm) wide which expose up to 40 % of the entire facade surface. It acts as a durable drainage plane, channeling bulk (liquid) water from wind-driven rain and snow to the outside of the structure. The watertight membrane helps protect the building enclosure from damaging effects of moisture infiltration. Its high vapor permeability allows moisture within the cavity to escape swiftly. DELTA®-FASSADE S is Class B fire-rated. Its performance is unaffected by surfactants.
Highly tear-resistant polyester substrate with a special, highly UV-stabilized acrylic coating
DELTA®-FASSADE S is very light-weight and tear-resistant, making installation fast, easy, and reliable. This technologically advanced membrane withstands the rigors of jobsites, as well as tough wind and weather.
| Product name | DELTA®-FASSADE S | |
|---|---|---|
| Color | black | |
| Material | PET substrate with UV stabile acrylic coating | |
| Water vapor transmission | 516.6 g/m²/24 h | ASTM E96-05, Proc. A |
| Permeance | 74.5 perms [grains/h/ft²/in Hg] | ASTM E96-05, Proc. A |
| Breaking load | MD 103.6 lb/2in CD 62.6 lb/2in |
ASTM D5035-06 |
| Elongation at break | MD 36.8 % CD 47.8 % |
ASTM D5035-06 |
| Tear resistance |
MD 1916 g CD 2564 g |
ASTM D1922-06a |
| Trapezoid tearing strength |
MD 23.1 lb CD 15.9 lb |
ASTM D4533-04 |
| Fastener pull-through force | 211.3 N | ASTM D3462-03 |
| Water penetration resistance | 103.8 cm | CAN/CGSB-4.2 #26.3-95 |
| Water impact penetration resistance | no water passing | AATCC 42-2000 |
| Flame Spread | 70 NFPA Class B; UBC Class II |
ASTM E84-09 |
| Smoke developed |
80 NFPA Class B; UBC Class II |
ASTM E84-09 |
| Air permeance | 0.9 l/(s x m²) @ 75 Pa | ASTM E2178 |
| Temperature range | -40 °F to +176 °F (-40 °C to +80 °C) |
|
| Mass per unit area | approx. 7.9 oz/yd² (270g/m²) | CSA A220.1-06 4.4.4 |
| Roll weight | approx. 44 lb (20 kg) | |
| Roll length | 164 ft (50 m) | |
| Roll width | 4.92 ft (1.5 m) | |
| Maximum UV (sunlight) Exposure (prior to installation of cladding) | 3 months | Always cover as soon as possible |
| Service life expectancy | > 25 years, if installed behind cladding systems that have open joints of up to 2” (50 mm) width which expose no more than 40 % of the entire facade surface. |